857 research outputs found

    A General Approach to Optomechanical Parametric Instabilities

    Full text link
    We present a simple feedback description of parametric instabilities which can be applied to a variety of optical systems. Parametric instabilities are of particular interest to the field of gravitational-wave interferometry where high mechanical quality factors and a large amount of stored optical power have the potential for instability. In our use of Advanced LIGO as an example application, we find that parametric instabilities, if left unaddressed, present a potential threat to the stability of high-power operation

    Thermo-optic noise in coated mirrors for high-precision optical measurements

    Get PDF
    Thermal fluctuations in the coatings used to make high-reflectors are becoming significant noise sources in precision optical measurements and are particularly relevant to advanced gravitational wave detectors. There are two recognized sources of coating thermal noise, mechanical loss and thermal dissipation. Thermal dissipation causes thermal fluctuations in the coating which produce noise via the thermo-elastic and thermo-refractive mechanisms. We treat these mechanisms coherently, give a correction for finite coating thickness, and evaluate the implications for Advanced LIGO

    Optimal configurations of filter cavity in future gravitational-wave detectors

    Full text link
    Sensitivity of future laser interferometric gravitational-wave detectors can be improved using squeezed light with frequency-dependent squeeze angle and/or amplitude, which can be created using additional so-called filter cavities. Here we compare performances of several variants of this scheme, proposed during last years, assuming the case of a single relatively short (tens of meters) filter cavity suitable for implementation already during the life cycle of the second generation detectors, like Advanced LIGO. Using numerical optimization, we show that the phase filtering scheme proposed by Kimble et al [Phys.Rev.D 65, 022002 (2001)] looks as the best candidate for this scenario.Comment: 17 pages, 5 figure

    Self-cooling of a movable mirror to the ground state using radiation pressure

    Full text link
    We show that one can cool a micro-mechanical oscillator to its quantum ground state using radiation pressure in an appropriately detuned cavity (self-cooling). From a simple theory based on Heisenberg-Langevin equations we find that optimal self-cooling occurs in the good cavity regime, when the cavity bandwidth is smaller than the mechanical frequency, but still larger than the effective mechanical damping. In this case the intracavity field and the vibrational mechanical mode coherently exchange their fluctuations. We also present dynamical calculations which show how to access the mirror final temperature from the fluctuations of the field reflected by the cavity.Comment: 4 pages, 3 figure

    Readout and Control of a Power-recycled Interferometric Gravitational-wave Antenna

    Get PDF
    Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes has been enhanced by adding multiple coupled optical resonators. The use of optical cavities is essential for reaching the required sensitivity, but sets challenges for the control system which must maintain the cavities near resonance. The goal for the strain sensitivity of the Laser Interferometer Gravitational-wave Observatory (LIGO) is 10^-21 rms, integrated over a 100 Hz bandwidth centered at 150 Hz. We present the major design features of the LIGO length and frequency sensing and control system which will hold the differential length to within 5 10^-14 m of the operating point. We also highlight the restrictions imposed by couplings of noise into the gravitational wave readout signal and the required immunity against them.Comment: Presentation at ICALEPCS 2001, San Jose, November 2001, (WECT003), 3 page

    Measurement of radiation-pressure-induced optomechanical dynamics in a suspended Fabry-Perot cavity

    Get PDF
    We report on experimental observation of radiation-pressure induced effects in a high-power optical cavity. These effects play an important role in next generation gravitational wave (GW) detectors, as well as in quantum non-demolition (QND) interferometers. We measure the properties of an optical spring, created by coupling of an intense laser field to the pendulum mode of a suspended mirror; and also the parametric instability (PI) that arises from the nonlinear coupling between acoustic modes of the cavity mirrors and the cavity optical mode. Specifically, we measure an optical rigidity of K=3Ă—104K = 3 \times 10^4 N/m, and PI value R=3R = 3.Comment: 4 pages, 3 figure

    Length Sensing and Control for AdLIGO

    No full text
    LIGO Document T060272-00-I (2006

    Frequency noise and intensity noise of next-generation gravitational-wave detectors with RF/DC readout schemes

    Get PDF
    The sensitivity of next-generation gravitational-wave detectors such as Advanced LIGO and LCGT should be limited mostly by quantum noise with an expected technical progress to reduce seismic noise and thermal noise. Those detectors will employ the optical configuration of resonant-sideband-extraction that can be realized with a signal-recycling mirror added to the Fabry-Perot Michelson interferometer. While this configuration can reduce quantum noise of the detector, it can possibly increase laser frequency noise and intensity noise. The analysis of laser noise in the interferometer with the conventional configuration has been done in several papers, and we shall extend the analysis to the resonant-sideband-extraction configuration with the radiation pressure effect included. We shall also refer to laser noise in the case we employ the so-called DC readout scheme.Comment: An error in Fig. 10 in the published version in PRD has been corrected in this version; an erratum has been submitted to PRD. After correction, this figure reflects a significant difference in the ways RF and DC readout schemes are susceptible to laser noise. In addition, the levels of mirror loss imbalances and input laser amplitude noise have also been updated to be more realistic for Advanced LIG

    To the practical design of the optical lever intracavity topology of gravitational-wave detectors

    Full text link
    The QND intracavity topologies of gravitational-wave detectors proposed several years ago allow, in principle, to obtain sensitivity significantly better than the Standard Quantum Limit using relatively small anount of optical pumping power. In this article we consider an improved more ``practical'' version of the optical lever intracavity scheme. It differs from the original version by the symmetry which allows to suppress influence of the input light amplitude fluctuation. In addition, it provides the means to inject optical pumping inside the scheme without increase of optical losses. We consider also sensitivity limitations imposed by the local meter which is the key element of the intracavity topologies. Two variants of the local meter are analyzed, which are based on the spectral variation measurement and on the Discrete Sampling Variation Measurement, correspondingly. The former one, while can not be considered as a candidate for a practical implementation, allows, in principle, to obtain the best sensitivity and thus can be considered as an ideal ``asymptotic case'' for all other schemes. The DSVM-based local meter can be considered as a realistic scheme but its sensitivity, unfortunately, is by far not so good just due to a couple of peculiar numeric factors specific for this scheme. From our point of view search of new methods of mechanical QND measurements probably based on improved DSVM scheme or which combine the local meter with the pondermotive squeezing technique, is necessary.Comment: 27 pages, 6 figure

    Adaptive thermal compensation of test masses in advanced LIGO

    Get PDF
    As the first generation of laser interferometric gravitational wave detectors near operation, research and development has begun on increasing the instrument's sensitivity while utilizing the existing infrastructure. In the Laser Interferometer Gravitational Wave Observatory (LIGO), significant improvements are being planned for installation in ~2007, increasing strain sensitivity through improved suspensions and test mass substrates, active seismic isolation, and higher input laser power. Even with the highest quality optics available today, however, finite absorption of laser power within transmissive optics, coupled with the tremendous amount of optical power circulating in various parts of the interferometer, result in critical wavefront deformations which would cripple the performance of the instrument. Discussed is a method of active wavefront correction via direct thermal actuation on optical elements of the interferometer. A simple nichrome heating element suspended off the face of an affected optic will, through radiative heating, remove the gross axisymmetric part of the original thermal distortion. A scanning heating laser will then be used to remove any remaining non-axisymmetric wavefront distortion, generated by inhomogeneities in the substrate's absorption, thermal conductivity, etc. A proof-of-principle experiment has been constructed at MIT, selected data of which are presented.Comment: 11 pages, 7 figures, submitted to Classical and Quantum Gravit
    • …
    corecore